VEVOR 5 CFM Two-Stage Vacuum Pump, 1/2 HP, Sparkless A2L Design

VEVOR 5 CFM Two-Stage Vacuum Pump, 1/2 HP, Sparkless A2L Design

$129.90Wholesale price, no minimum order

Pump Type:
Power:

Key Features

The two-stage rotary vane design targets a deeper, more stable vacuum than a basic single-stage pump.
The 5 CFM / 142 L/min displacement and 1/2 HP motor balance evacuation speed with a body that remains movable.
The listing describes a sparkless A2L design with an electronic centrifugal switch for R32 and R1234yf service.
A gas-ballast valve helps handle condensable vapours, while the backflow-prevention valve and manual ball valve protect the service setup when the pump stops.
The oil sight glass, cooling fan, handle and three common inlet sizes make routine setup and oil checks straightforward.

In stock

Genuine ProductWholesale Price, No MinimumSame Manufacturer WarrantyShips from US Warehouse
We accept: VisaMCAmexDiscover
We accept:VISAMCAMEXDISC
Free US ShippingFree to the 48 contiguous US states
Ships in 1-2 Business DaysStandard delivery in 2-6 business days
30-Day ReturnsEasy returns for peace of mind
Manufacturer WarrantyCovered by the VEVOR warranty

Authorized VEVOR ResellerGenuine, factory sealed VEVOR stock

📦 Free shipping to the 48 contiguous US states · Ships within 1-3 business days, arrives in 2-5 business days · 30-day returns and manufacturer warranty
SKU: KDZKB5CFM375WZ63JV1 Category:

Quick Answer

This 5 CFM two-stage rotary vane pump uses a 1/2 HP motor and is listed at 2.5 Pa, 25 microns and 0.003 mbar ultimate vacuum. It has a gas-ballast valve, a sparkless A2L-oriented design for R32 and R1234yf, and three service inlets. The box includes two bottles of oil.

Description

At a Glance

This 5 CFM two-stage rotary vane pump uses a 1/2 HP motor and is listed at 2.5 Pa, 25 microns and 0.003 mbar ultimate vacuum. It has a gas-ballast valve, a sparkless A2L-oriented design for R32 and R1234yf, and three service inlets. The box includes two bottles of oil.

VP245Model5 CFM / 142 L/minFree air displacementTwo-stageStage1/2 HP / 375 WMotor115V / 60 HzVoltage / frequency2.5 Pa / 25 microns / 0.003 mbarUltimate vacuum1/4 in. SAE male, 3/8 in. SAE male and 1/2 in. ACME maleIntake fittings12.7 x 8.8 x 9.6 inDimensions

5 CFM / 142 L/min Two-Stage Vacuum Pump

This 5 CFM two-stage rotary vane pump uses a 1/2 HP motor and is listed at 2.5 Pa, 25 microns and 0.003 mbar ultimate vacuum. It has a gas-ballast valve, a sparkless A2L-oriented design for R32 and R1234yf, and three service inlets. The box includes two bottles of oil.

5 CFM two-stage A2L vacuum pump overview

What is in the box: Pump, user manual, one 330 ml oil bottle and one 230 ml oil bottle.

What 5 CFM / 142 L/min and a two-stage design mean

Free air displacement tells you how much air the pump can move at its inlet under flow conditions. It is not the same as the flow rate once the system is near deep vacuum. A higher CFM pump tends to shorten the time needed to remove the initial volume of air, while the final micron reading depends on the pump’s ultimate vacuum, the condition of its oil, the hoses, the manifold seals and the leak tightness of the system.

This is the stronger vacuum option for technicians who expect to work with A2L refrigerants or need a deeper final vacuum. The listing describes sparkless operation and A2L compatibility, but that does not replace local service rules, refrigerant handling procedures and the equipment-specific manufacturer instructions. Use a micron gauge and confirm the system holds vacuum before charging.

Fittings and service setup

The listed intake fittings are 1/4 in. SAE male, 3/8 in. SAE male and 1/2 in. ACME male. Check the thread and flare style against your manifold before connecting a hose. Use short, pressure-rated service hoses, replace damaged gaskets and keep the hose ends capped when they are not in use. A small air leak or a worn Schrader-core tool can make a good pump look weak because the micron reading never settles.

Where this pump fits

Use it for HVAC and refrigeration service, automotive AC work, vacuum bagging, wood stabilization and laboratory degassing where 5 CFM and a two-stage pump are appropriate. The 25-micron target is useful when moisture removal and leak confirmation matter. A 3.5 CFM single-stage pump can still handle smaller routine jobs where the fastest pull is not required.

  • Evacuation: pull down with the service valves arranged according to the equipment procedure, then let the pump run long enough for moisture to leave the system.
  • Leak check: isolate the pump and watch the vacuum hold. A rising gauge points to a leak or outgassing, not a reason to add refrigerant.
  • Oil check: keep oil between the sight-glass marks and replace it when it looks cloudy, dark or contaminated.
  • Heat: use the cooling fan and give the pump a sensible duty cycle; a hot body is a warning to stop and inspect.

Choosing this pump

Choose this pump when R32 or R1234yf service, two-stage depth and a 5 CFM workflow are priorities. Choose the 7 CFM model for more displacement, or a standard 3.5 to 4.5 CFM single-stage pump for light jobs where the extra complexity is not needed.

Before the first job

Confirm the supply voltage, set the pump on a level surface and check that the exhaust is not blocked. Fill the oil to the correct mark, close the inlet valve, and run a short no-load check while watching for unusual noise or oil movement. For refrigerant work, follow the equipment maker’s evacuation target, use a micron gauge, and never use vacuum alone as proof that a system is leak-free.

Wholesale pricing

One unit, wholesale pricing. The listed price is the wholesale rate for one pump. There is no minimum order quantity and no separate tier price, so buying one unit and buying several units use the same listed unit price.

Performance & Applications

Key Features

oil sight glass
Sight Glass
exhaust fitting
Exhaust Fitting(Oil Fill Cap)
fan cover
Fan Cover

three-quarter view

Specifications

BrandVEVOR
ModelVP245
Voltage115V/60 Hz
Free Air Displacement5 CFM;142 L/min
Ultimate Vacuum2.5 Pa; 25 Microns; 0.003 mbar
Motor375W; 1/2 HP
Intake Fitting1/4" SAE male; 3/8" SAE male; 1/2" ACME male

0 reviews for VEVOR 5 CFM Two-Stage Vacuum Pump, 1/2 HP, Sparkless A2L Design

Customer reviews

No reviews found

No reviews match your current filters. Try adjusting or clearing your filters to see more reviews.

Be the first to review “VEVOR 5 CFM Two-Stage Vacuum Pump, 1/2 HP, Sparkless A2L Design”

Your email address will not be published. Required fields are marked *

0 / 100

Drag & drop files here or browse

Images: up to 5 files, max 5MB each | Videos: up to 2 files, max 50MB each, 60 sec max

Frequently Asked Questions

Q: What does 5 CFM / 142 L/min mean on this pump?

A: CFM is free air displacement at the inlet. It describes how quickly the pump moves air before the system is at deep vacuum; the final result also depends on the pump's ultimate vacuum, hoses, seals and the leak tightness of the system.

Q: Is this a two-stage pump?

A: Yes. The specification table describes this model as two-stage.

Q: What fittings can I connect?

A: Intake fittings: 1/4 in. SAE male, 3/8 in. SAE male and 1/2 in. ACME male. Check the thread, flare and hose gasket against your manifold before connecting.

Q: What does 2.5 Pa / 25 microns / 0.003 mbar ultimate vacuum mean?

A: The page lists 2.5 Pa / 25 microns / 0.003 mbar ultimate vacuum. A lower pressure or micron number represents a deeper vacuum, but the system must be leak-free for the reading to settle.

Q: Does the box include gauges, hoses and oil?

A: Pump, user manual, one 330 ml oil bottle and one 230 ml oil bottle.

Q: Can it run on its listed voltage?

A: The voltage is listed as 115V / 60 Hz. Match that figure to the nameplate and the outlet before use.

Q: Can I use it with R32 or R1234yf?

A: Only when the product page and your service procedure say the pump is suitable for that refrigerant. The standard single-stage kits are not the R32 explosion-proof version. Use compatible hoses, gauges and recovery equipment.

Q: How often should I change the oil?

A: Check the sight glass before every job and change the oil when it becomes cloudy, dark or contaminated. A moisture-loaded system may require a change sooner. Follow the manual and the application's oil guidance.

Q: Can I carry it between jobs?

A: The listed pump-body dimensions are 12.7 x 8.8 x 9.6 in. Check the filled weight and case layout before planning to carry it with one hand.

Q: What is the wholesale price for one unit?

A: The listed price applies to one unit. There is no minimum order quantity and no separate tier price.